Maximum deflection of symmetric wall-frame buildings
Abstract
The system of governing differential equations of lateral deflection of symmetric multi-storey buildings subjected to uniformly distributed horizontal load is presented. It is shown that the “standard” equivalent column approach (when the stiffnesses of the bracing units are added up) is only applicable to the deflection analysis in the rare case when the system only consists of shear walls and a single framework. When the bracing system contains more frameworks, then a more sophisticated approach is needed where the full interaction between the vertical elements in bending and shear may need to be taken into account.
Two new methods are developed for the determination of the maximum deflection of mixed bracing systems consisting of frameworks and shear walls: one is very simple while the other one is more accurate. The accuracy of both procedures is demonstrated using the results of over 200 bracing systems. The error range of the more accurate method is -4% to +4% when the buildings contain frameworks and shear walls/cores. A worked example and step-by-step instructions are presented to aid practical application.
Keywords:
deflection, continuum method, multi-storey buildings, horizontal loadPublished Online
How to Cite
Issue
Section
License
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (see The Effect of Open Access). As soon as the paper is accepted, finally submitted and edited, the paper will appear in the "OnlineFirst" page of the journal, thus from this point no other internet-based publication is necessary.